Iris-fixated toric phakic intraocular lens: Three-year follow-up

2006

Purpose To evaluate the 3-year safety, efficacy, predictability, and stability of iris-fixated toric phakic intraocular lens (pIOL) implantation for the correction of myopia or hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg University, Mainz, and Department of Ophthalmology, University Clinic, Bochum, Germany. Methods A prospective clinical trial of 40 eyes of 23 patients with high ametropia and astigmatism was conducted. Best spectacle-corrected visual acuity (BSCVA), uncorrected visual acuity, refraction, astigmatism, intraocular pressure, slitlamp biomicroscopy, and indirect ophthalmoscopy were measured preoperatively and postoperatively. Results Of t…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIrisIntraocular lensAstigmatismRefraction OcularPhakic intraocular lensOphthalmoscopyPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineHumansMedicineProspective StudiesIntraoperative ComplicationsIntraocular PressureDioptremedicine.diagnostic_testbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsRefractive Surgical ProceduresOphthalmoscopyToric lensOphthalmologyTreatment OutcomeFemaleSurgerysense organsmedicine.symptombusinessFollow-Up StudiesJournal of Cataract and Refractive Surgery
researchProduct

A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma

2014

Purpose To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). Design Prospective, multicenter, randomized, single-masked, controlled clinical trial. Participants One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. Methods On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Wa…

MaleIntraocular pressureVisual acuityMinimally invasive glaucoma surgerymedicine.medical_treatmentVisual AcuityGlaucomalaw.inventionRandomized controlled trialLens Implantation Intraocularlaw80 and overMedicineSingle-Blind MethodProspective StudiesProspective cohort studyGlaucoma Drainage ImplantsAged 80 and overIntraocularMedicine (all)Adult; Aged; Aged 80 and over; Antihypertensive Agents; Female; Follow-Up Studies; Glaucoma Open-Angle; Humans; Intraocular Pressure; Lens Implantation Intraocular; Limbus Corneae; Male; Middle Aged; Prospective Studies; Prosthesis Implantation; Single-Blind Method; Tonometry Ocular; Visual Acuity; Visual Fields; Young Adult; Glaucoma Drainage Implants; Phacoemulsification; Stents; Ophthalmology; Medicine (all)Middle AgedOpen-AngleFemaleStentsmedicine.symptomLens ImplantationGlaucoma Open-AngleAdultmedicine.medical_specialtyLimbus CorneaeTonometryProsthesis ImplantationTonometry OcularYoung AdultOphthalmologyOcularHumansAntihypertensive AgentsIntraocular PressureAgedPhacoemulsificationbusiness.industryGlaucomaPhacoemulsificationCataract surgerymedicine.diseaseOphthalmologyVisual FieldsbusinessFollow-Up Studies
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Ultraviolet radiation at Mediterranean latitudes and protection efficacy of intraocular lenses.

2011

Summary Purpose After determining the mean intensity of ultraviolet radiation to which the human eye is exposed at Mediterranean latitudes, this data is used to evaluate the efficacy of the ultraviolet filters incorporated into various intraocular lenses. Methods Ultraviolet radiation measured at Mediterranean latitudes was used as a reference for the theoretical calculation of the amount of radiation to which the human eye is exposed. The spectral transmission curve from 290 to 380 nm was measured for 10 IOLs using a UV/VIS Perkins-Elmer Lambda 800 spectrometer. Results At Mediterranean latitudes, at sea level, with a mean annual solar irradiation of 50 j/cm 2 , the human eye receives a qu…

Materials sciencegenetic structuresUltraviolet Raysmedicine.medical_treatmentIntraocular lensRadiationmedicine.disease_causelaw.inventionOpticsRadiation ProtectionlawLens CrystallinemedicineAnimalsHumansIrradiationLenses Intraocularbusiness.industryMediterranean RegionAlbedoeye diseasesLens (optics)OphthalmologyWavelengthmedicine.anatomical_structureSunlightHuman eyesense organsRabbitsbusinessUltravioletJournal francais d'ophtalmologie
researchProduct

Modulation transfer function: Rigid versus foldable phakic intraocular lenses

2008

Purpose To study in a standard eye model the changes in modulation transfer function (MTF) of a monofocal intraocular lens (IOL) when a phakic IOL (pIOL) is placed in the anterior chamber, compare the MTFs of the rigid Artisan pIOL and foldable Artiflex pIOL, and evaluate the temporal evolution of the MTF of the foldable pIOL after the mechanical stress the pIOL undergoes when injected. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods The MTF values of the IOLs were calculated from the cross-line spread function recorded with the Opal Vector System. The measurements were taken using an eye model following the British and EN-ISO standards with 2.0 mm, 3.0 mm, 4.0 mm…

Phakic Intraocular Lensesmedicine.medical_specialtyMaterials scienceOptical PhenomenaAnterior Chambermedicine.medical_treatmentIntraocular lensPhakic intraocular lensModels BiologicalSensory SystemsOptical qualityPupillaw.inventionLens (optics)OphthalmologyLens Implantation IntraocularlawOphthalmologyOptical transfer functionMyopiamedicineHumansSurgeryPhakic iolDioptreJournal of Cataract and Refractive Surgery
researchProduct

Foldable toric intraocular lens for astigmatism correction in cataract patients.

2007

PURPOSE: To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING: Ophthalmology Service, Donostia Hospital, San Sebastian, Spain. METHODS: This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having cataract surgery. Bilateral implantation of the AcrySof toric IOL was performed after phacoemulsification. The uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), residual refractive sphere, residual keratometric and refractive cylinders, and toric IOL axis were measured. RESU…

MaleRefractive errormedicine.medical_specialtygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensAstigmatismRefraction OcularVision disorderLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesDioptreAgedAged 80 and overLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismPhacoemulsificationCataract surgeryMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyOptometrySurgeryFemalesense organsmedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma

2020

indexation en cours.; PURPOSE: This study investigated the efficacy and safety of a cross-linked collagen stent (XEN 45) with or without cataract surgery in the treatment of glaucoma. SETTING: Real-life setting. DESIGN: Prospective, open-label, multicenter clinical trial. METHODS: Eligible patients with glaucoma inadequately controlled by treatment, or poor compliance or intolerance to topical therapy were included. Patients were divided into those with implant only (solo group; phakic and pseudophakic patients) and implant combined with cataract surgery (combo group). Differences in average intraocular pressure (IOP) and number of medications between baseline and study end (12 months), and…

MaleIntraocular pressuregenetic structuresmedicine.medical_treatmentVisual AcuityGlaucomasurgery0302 clinical medicineLens Implantation IntraocularimplantationProspective StudiesGlaucoma Drainage ImplantsAged 80 and overDry needlingMiddle AgedSensory Systems3. Good healthEuropeTreatment OutcomeFemaleStentsGlaucoma Open-Anglesafetymedicine.medical_specialtyintraocular-pressurepredictive-value03 medical and health sciencesTonometry OcularmedicineHumans[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrganssuccessIntraocular PressureAgedbusiness.industryStentPhacoemulsificationCataract surgerymedicine.diseaseeye diseasesSurgeryClinical trialOphthalmologyphacoemulsification030221 ophthalmology & optometryImplantsense organsbusiness030217 neurology & neurosurgery[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyFollow-Up Studies
researchProduct

Effect of head position on refraction in aphakic and phakic silicone-filled eyes.

1997

BACKGROUND The refraction of the eye is altered significantly after the instillation of silicone oil into the vitreous cavity because of the silicone oil's high refractive index. The degree of the refractive change shows diurnal variation and depends on the patient's head position. PATIENTS AND METHODS To analyze the degree and time course of refractive changes with respect to head position, the authors performed objective refraction in five aphakic and five phakic silicone oil-instilled eyes with attached maculae using an automatic hand-held refractometer. In each patient, 25 measurements were taken at short intervals using a hand-held autorefractometer with the patient in different positi…

Malemedicine.medical_specialtySupine positionVisual acuitygenetic structuresPseudophakiaPostureVisual AcuityAphakia PostcataractRefraction Ocularchemistry.chemical_compoundSiliconeRefractometerOphthalmologyMedicineHumansSilicone Oilsskin and connective tissue diseasesDioptreLenses Intraocularbusiness.industryRetinal DetachmentGeneral MedicineMiddle AgedRefractioneye diseasesSilicone oilOphthalmologyRefractometrychemistryHead positionFemalesense organsmedicine.symptombusinessHeadRetina (Philadelphia, Pa.)
researchProduct

Intraocular lens centration and stability: efficacy of current technique and technology

2008

Purpose of review The manuscript presents a review of recently published studies analyzing different methodologies to assess centration and stability of intraocular lenses after implantation. Recent findings Considering that there is no current gold standard for centration and stability of intraocular lenses after implantation, we have summarized the different techniques used clinically for intraocular lenses centration and stability estimation. We have described the use of Scheimpflug imaging, the anterior segment optical coherence tomography and photography analysis used for lens position estimation. Techniques used to assess lens rotation are based on image analysis on digital retroillum…

Rotationgenetic structuresmedicine.medical_treatmentScheimpflug principleImage processingIntraocular lenslaw.inventionLens Implantation IntraocularOptical coherence tomographyAnterior Eye SegmentlawImage Processing Computer-AssistedPhotographymedicineHumansLenses Intraocularmedicine.diagnostic_testbusiness.industryGeneral MedicineCentrationeye diseasesLens (optics)OphthalmologyIntraocular lensessense organsbusinessTomography Optical CoherenceBiomedical engineeringCurrent Opinion in Ophthalmology
researchProduct

Compression forces of haptics of freely rotating posterior chamber intraocular lenses.

1998

Abstract Purpose: To measure the compressive forces of the haptics of 28 intraocular lens (IOL) models for different modes of compression and compare the results of two types of measurements. Setting: Department of Ophthalmology, Central Hospital of Central Finland, Jyvaskyla, Finland. Methods: The haptics of 28 types of IOLs were compressed to a diameter of 9.0 mm between curved anvils. The compression forces in the plane of compression (i.e., in the plane of the optics) were measured at 0.5 mm intervals. During compression, the optics and the haptics were free to rotate with respect to the anvils. The results were compared with those of earlier measurements in which the optics were held f…

Lenses IntraocularMaterials scienceCompressive Strengthbusiness.industryPlane (geometry)medicine.medical_treatmentStiffnessIntraocular lensCompression (physics)RotationSensory Systemslaw.inventionLens (optics)OphthalmologyOpticsLens Implantation IntraocularlawmedicinePerpendicularSurgerymedicine.symptombusinessHaptic technologyJournal of cataract and refractive surgery
researchProduct